Beta · Open Source ACAP

Put your Axis devices on the building management system

Your BMS can read what Axis cameras and sensors already know, such as inputs, tampering, people counts and air quality, as standard BACnet objects. No gateway or middleware needed.

Try the live preview Download
Disclaimer: This is an independent, community-developed ACAP package and is not an official Axis Communications product. It is not affiliated with, endorsed by, or supported by Axis Communications AB. Use at your own risk.
Why you'd use it

The camera already knows. Now the building does too.

Axis devices detect a lot more than video. This app makes those readings available to building management systems in the language they speak.

Adjust the HVAC to how many people are in the room

Publish the occupancy count from AXIS Object Analytics as a BACnet value the BMS can use for ventilation, heating and lighting.

Put the air quality readings in the BMS

An AXIS D6310 sensor publishes temperature, humidity, CO2, particulates and vaping detection as 16 ready-made objects.

Tell the operator when something is wrong

Tampering, a digital input, or a camera that stops recording shows up as a status the BMS can raise an alarm on.

How it works

Pick the events, the BMS reads the values

You choose which camera events to publish on the app's settings page. Each one becomes a BACnet object that updates the moment the event changes.

On the camera or sensor

Inputs and outputsPhysical and virtual I/O ports
Tampering and recording statusCamera health the operator should know about
Object AnalyticsPeople counts and occupancy in an area
Air qualityTemperature, CO2, particulates, vaping (AXIS D6310)

BACnet Server, on the device

Turns events into objectsAnalog, binary and multi-state values
Pushes changesChange-of-value notifications, no constant polling
Read-only by designNothing on the camera can be changed over BACnet

Your building systems

Building management systemDiscovers the device like any other BACnet controller
Alarms and dashboardsValues update within a second of the event
Any BACnet/IP clientReads every property of the device and objects

BACnet/IP has no login, so anyone who can reach the device can read the published values. Keep it on your building automation network.

Try it

This is the real settings page

The same page that runs on the device, filled with sample data from an air quality sensor. Try adding an object to see which events you can choose from.

https://192.168.0.90/local/BACnet_Server/index.html
Sample data
Sample data. There's no device behind this preview, and nothing you change is saved. Open the preview full screen →
Features

Made to fit into a building project

No gateway

The camera or sensor appears on the BACnet network as its own device. Nothing to install in between.

Only events the device has

The settings page lists the events this particular device supports, so you can't pick one it doesn't.

Change of value

The BMS can subscribe and be told when a value changes, instead of asking over and over.

Safe to connect

Every property is read-only, and the BACnet device stays off until you switch it on.

Ready-made example

A tested object list for the AXIS D6310 air quality sensor, with the correct units, loads with a single command.

Keeps its settings

Device settings and objects survive restarts and upgrades. Object IDs don't change unless you change them.

Download

Get BACnet Server

Free and open source. Pick the package for your camera's processor.

BACnet Server

Latest release on GitHub
AXIS OS11.11 to 13
ProcessorAARCH64 (tested on AXIS OS 12.11 and 13.0) · ARMv7 (built, not yet tested on a device)
BACnetBACnet/IP, BACnet Smart Sensor (B-SS) profile, protocol revision 28
StatusBeta

Not sure which package? Most recent Axis cameras use AARCH64. If the camera refuses to install it, use ARMv7 instead.

Install

Up and running in a few minutes

1
Download the packagePick AARCH64 or ARMv7 above.
2
Install it on the deviceIn the web interface, go to Apps → Add app, upload the file and start the app.
3
Choose what to publishGo to Apps → BACnet Server → Open and add an object for each event you want the BMS to see.
4
Switch the device onThe BACnet device is off after installation. Enable it, and it appears on the network on UDP port 47808.
5
Discover it from the BMSRun a device discovery (Who-Is) from the building management system on the same network.
Questions

Good to know

Can the BMS control the camera?

No. This version is read-only: the BMS can read values and subscribe to changes, but it can't write anything.

Does the BMS need to be on the same network?

Yes, on the same subnet, or with a BACnet broadcast management device (BBMD) on the network. Foreign device registration isn't supported yet.

Is it BTL certified?

No. It's a beta built on the open-source bacnet-stack, and it uses that project's default vendor ID. Some projects require certification or a vendor ID of your own, which this beta doesn't provide.

Which devices has it been tested on?

An AXIS P3288-LV camera on AXIS OS 12.11 and an AXIS D6310 Air Quality Sensor on AXIS OS 13.0, using standard BACnet tools.

How can I help?

If you try it with a building management system, please share how it went in the issues on GitHub. Feedback from real installations is very welcome.